Error:100


Description:Voltage difference is too large
Solution:Return to factory for repair

Error:110


Description:Charging Overvoltage Protection
Solution:Disconnect charger

Error:140


Description:Discharge undervoltage protection
Solution:Connect the charger

Error:150


Description:Discharge over temperature protection
Solution:Wait for the device to cool down

Error:160


Description:Discharge undertemperature protection
Solution:Keep the product at the right temperature

Error:170


Description:Temperature error
Solution:Restart device

Error:170


Description:Temperature error
Solution:Restart device

Error:200


Description:Abnormal communication
Solution:Restart device

Error:201


Description:Charging communication abnormal
Solution:Restart device

Error:310


Description:Air pump short circuit protection
Solution:Restart device

Error:320


Description:Air pump overcurrent protection
Solution:Restart device

Error:320


Description:Air pump overcurrent protection
Solution:Restart device

Error:330


Description:When starting,the current air Pressure is greater than the set air pressure
Solution:Reset the proper air pressure

Error:410


Description:During start-up, undervoltage protection
Solution:Connect charger

Error:411


Description:Before start-up, undervoltage protection
Solution:Connect charger

Error:420


Description:Start over temperature protection
Solution:Wait for the device to cool down

Error:430


Description:External battery voltage greater than device voltage
Solution:1. The displayed voltage is lower than 12V, and the voltage of the device is low. Please connect the charger to recharge it. 2.If the displayed voltage is higher than 12V, the car battery is normal; or the voltage of the car battery is too high, which is not suitable for this product. Please use an jump starter that supports higher voltage.

Error:440


Description:Reverse connection of clip
Solution:Connect the battery correctly

Error:450


Description:Clip shorted
Solution:Connect the battery correctly

Error:470


Description:Voltage difference protection before starting
Solution:Return to factory for repair

Error:480


Description:Wait 30 seconds for the next boot
Solution:Wait 30 seconds and start again